National Healthcare Quality and Disparities Report
Latest available findings on quality of and access to health care
Data
- Data Infographics
- Data Visualizations
- Data Tools
- Data Innovations
- All-Payer Claims Database
- Healthcare Cost and Utilization Project (HCUP)
- Medical Expenditure Panel Survey (MEPS)
- AHRQ Quality Indicator Tools for Data Analytics
- State Snapshots
- United States Health Information Knowledgebase (USHIK)
- Data Sources Available from AHRQ
Search All Research Studies
Topics
- Adverse Events (2)
- Cardiovascular Conditions (4)
- Chronic Conditions (2)
- Comparative Effectiveness (4)
- Elderly (2)
- Evidence-Based Practice (1)
- Guidelines (1)
- Heart Disease and Health (6)
- Hospitalization (1)
- Hospital Readmissions (1)
- (-) Medical Devices (10)
- Medicare (3)
- Mortality (1)
- (-) Outcomes (10)
- Patient-Centered Outcomes Research (2)
- Quality of Care (1)
- Registries (2)
- Rehabilitation (1)
- Surgery (2)
AHRQ Research Studies
Sign up: AHRQ Research Studies Email updates
Research Studies is a compilation of published research articles funded by AHRQ or authored by AHRQ researchers.
Results
1 to 10 of 10 Research Studies DisplayedMentias A, Briasoulis A, Vaughan Sarrazin MS
Trends, perioperative adverse events, and survival of patients with left ventricular assist devices undergoing noncardiac surgery.
This longitudinal cohort study examined outcomes of noncardiac surgery (NCS) in patients with left ventricular assist devices (LVADs). This study examined patients enrolled in Medicare who had undergone durable LVAD implantation from January 2012 to November 2017 with follow-up through December 2017. Primary outcome after NCS was major adverse cardiovascular events (MACEs), defined as in-hospital or 30-day all-cause mortality, ischemic stroke, or intracerebral hemorrhage. Of the 8118 patients with LVAD, 1326 underwent NCS with 75.4% emergent or urgent, and 24.6% elective. Both elective and urgent or emergent NCS was associated with higher mortality early and late compared with patients with LVAD who did not undergo NCS.
AHRQ-funded; HS023104.
Citation: Mentias A, Briasoulis A, Vaughan Sarrazin MS .
Trends, perioperative adverse events, and survival of patients with left ventricular assist devices undergoing noncardiac surgery.
JAMA Netw Open 2020 Nov 2;3(11):e2025118. doi: 10.1001/jamanetworkopen.2020.25118..
Keywords: Heart Disease and Health, Cardiovascular Conditions, Surgery, Medical Devices, Chronic Conditions, Outcomes, Adverse Events
Bachmann JM, Duncan MS, Shah AS
Association of cardiac rehabilitation with decreased hospitalizations and mortality after ventricular assist device implantation.
This study examined whether outcomes of cardiac patients who had received ventricular assist device (VAD) implementation had decreased hospitalization and mortality with cardiac rehabilitation (CR). Medicare beneficiaries enrolled for disability or aged 65 years and older in 2014 were included. The investigators identified VAD recipients by diagnosis codes. It was found that each 5-year increase in age was associated with attending an additional 1.6 CR sessions and there was a 23% lower 1-year hospitalization risk and a 47% lower 1-year mortality risk.
AHRQ-funded; HS022990.
Citation: Bachmann JM, Duncan MS, Shah AS .
Association of cardiac rehabilitation with decreased hospitalizations and mortality after ventricular assist device implantation.
JACC Heart Fail 2018 Feb;6(2):130-39. doi: 10.1016/j.jchf.2017.11.002..
Keywords: Cardiovascular Conditions, Rehabilitation, Heart Disease and Health, Medical Devices, Surgery, Patient-Centered Outcomes Research, Outcomes, Mortality, Evidence-Based Practice, Hospitalization
Chen CY, Stevenson LW, Stewart GC
Real world effectiveness of primary implantable cardioverter defibrillators implanted during hospital admissions for exacerbation of heart failure or other acute co-morbidities: cohort study of older patients with heart failure.
The researchers examined the effectiveness of primary implantable cardioverter defibrillators (ICDs) in elderly patients receiving the device during a hospital admission for exacerbation of heart failure or other acute co-morbidities. They concluded that the benefits of primary ICD therapy seen in pivotal trials were not apparent in patients aged 66 or over who received ICDs during a hospital admission for exacerbation of heart failure or other acute co-morbidities.
AHRQ-funded; 290-2005-0016-I -TO3; HS017731.
Citation: Chen CY, Stevenson LW, Stewart GC .
Real world effectiveness of primary implantable cardioverter defibrillators implanted during hospital admissions for exacerbation of heart failure or other acute co-morbidities: cohort study of older patients with heart failure.
BMJ 2015 Jul 14;351:h3529. doi: 10.1136/bmj.h3529..
Keywords: Comparative Effectiveness, Elderly, Medical Devices, Heart Disease and Health, Outcomes
Masoudi FA, Go AS, Magid DJ
Age and sex differences in long-term outcomes following implantable cardioverter-defibrillator placement in contemporary clinical practice: findings from the Cardiovascular Research Network.
The objectives of this study were to characterize the risks of adverse outcomes in women and older patients. following implantable cardioverter-defibrillator placement with a focus on death, hospitalization, and complications. It concluded that the burden of adverse outcomes is substantial and varies according to patient age and sex. These differences in outcome generally do not vary according to baseline heart failure characteristics.
AHRQ-funded; 290050033; HS019814.
Citation: Masoudi FA, Go AS, Magid DJ .
Age and sex differences in long-term outcomes following implantable cardioverter-defibrillator placement in contemporary clinical practice: findings from the Cardiovascular Research Network.
J Am Heart Assoc 2015 Jun 2;4(6):e002005. doi: 10.1161/jaha.115.002005..
Keywords: Medical Devices, Cardiovascular Conditions, Patient-Centered Outcomes Research, Elderly, Outcomes
Walker J, Tucker LY, Goodney P
Adherence to endovascular aortic aneurysm repair device instructions for use guidelines has no impact on outcomes.
The authors reported on their long-term endovascular aortic aneurysm repair (EVAR) experience in a large multicenter registry with regard to adherence to instructions for use (IFU) guidelines. They found that overall mortality and aneurysm-related mortality were unaffected by IFU adherence, and that rates of endoleak and reintervention after initial EVAR were similar, suggesting that lack of IFU-based anatomic suitability was not a driver of outcomes.
AHRQ-funded; HS021581.
Citation: Walker J, Tucker LY, Goodney P .
Adherence to endovascular aortic aneurysm repair device instructions for use guidelines has no impact on outcomes.
J Vasc Surg 2015 May;61(5):1151-9. doi: 10.1016/j.jvs.2014.12.053.
.
.
Keywords: Adverse Events, Guidelines, Medical Devices, Outcomes
Bilchick KC, Stukenborg GJ
Comparative effectiveness of cardiac resynchronization therapy in combination with implantable defibrillator in patients with heart failure and wide QRS duration.
The researchers examined the long-term outcomes among Medicare patients with cardiac resynchronization therapy defibrillators (CRT-D) compared with those receiving standard implantable cardioverter defibrillators. They found that the greatest benefit of CRT-D was in patients with guideline-based class I recommendations for CRT-D. For these patients, there was a 17 percent reduction in risk of death.
AHRQ-funded; HS017693
Citation: Bilchick KC, Stukenborg GJ .
Comparative effectiveness of cardiac resynchronization therapy in combination with implantable defibrillator in patients with heart failure and wide QRS duration.
Am J Cardiol. 2014 Nov 15;114(10):1537-42. doi: 10.1016/j.amjcard.2014.08.017..
Keywords: Comparative Effectiveness, Medicare, Outcomes, Cardiovascular Conditions, Medical Devices
Khazanie P, Hammill BG, Qualls LG
Clinical effectiveness of cardiac resynchronization therapy versus medical therapy alone among patients with heart failure: analysis of the ICD Registry and ADHERE.
The researchers examined associations between cardiac resynchronization therapy with defibrillator (CRT-D) and mortality and readmission among patients with heart failure who received CRT-D in clinical practice, compared with those who received medical therapy alone. They found that CRT-D was associated with lower risks of mortality and readmission than medical therapy alone.
AHRQ-funded; HS021092
Citation: Khazanie P, Hammill BG, Qualls LG .
Clinical effectiveness of cardiac resynchronization therapy versus medical therapy alone among patients with heart failure: analysis of the ICD Registry and ADHERE.
Circ Heart Fail. 2014 Nov;7(6):926-34. doi: 10.1161/circheartfailure.113.000838..
Keywords: Comparative Effectiveness, Heart Disease and Health, Medical Devices, Hospital Readmissions, Outcomes
Borne RT, Peterson PN, Greenlee R
Temporal trends in patient characteristics and outcomes among Medicare beneficiaries undergoing primary prevention implantable cardioverter-defibrillator placement in the United States, 2006-2010.
Results from the National Cardiovascular Data Registry's Implantable Cardioverter-Defibrillator Registry. This study characterizing trends in clinical profiles and outcomes among Medicare patients undergoing primary implantable cardioverter-defibrillator implantation found only modest changes in clinical characteristics between 2006 and 2010. However, 6-month mortality and rehospitalization improved significantly over time, suggesting that there were meaningful improvements.
AHRQ-funded; HS019814
Citation: Borne RT, Peterson PN, Greenlee R .
Temporal trends in patient characteristics and outcomes among Medicare beneficiaries undergoing primary prevention implantable cardioverter-defibrillator placement in the United States, 2006-2010.
Circulation. 2014 Sep 2;130(10):845-53. doi: 10.1161/CIRCULATIONAHA.114.008653..
Keywords: Medical Devices, Outcomes, Medicare, Registries, Quality of Care
Setoguchi SR, Warner Stevenson L, Stewart GC
Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure.
This study assessed the potential contribution of unmeasured general health status to patient selection in assessments of implantable cardioverter-defibrillator (ICD) therapy. In a group of heart failure patients, those who received ICD therapy were younger and had lower ejection fraction and more cardiac admissions to hospital but fewer non-cardiac admissions. The lower risks of measured outcomes likely reflect unmeasured differences in comorbidity and frailty.
AHRQ-funded; 29020050016I; HS017731
Citation: Setoguchi SR, Warner Stevenson L, Stewart GC .
Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure.
BMJ. 2014 May 8;348:g2866. doi: 10.1136/bmj.g2866..
Keywords: Medical Devices, Outcomes, Registries, Heart Disease and Health, Medicare
Al-Khatib SM, Han JY, Edwards R
Do patients with a left ventricular ejection fraction between 30% and 35% benefit from a primary prevention implantable cardioverter defibrillator?
The researchers used data from randomized clinical trials involving patients with systolic heart failure who had received implantable cardioverter-defibrillators and compared outcomes for those whose left ventricular ejection fractions (LVEFs) was between 30 percent and 35 percent with those whose LVEF was less than 30 percent. The sample size was too small to permit any important conclusions.
AHRQ-funded; HS018505
Citation: Al-Khatib SM, Han JY, Edwards R .
Do patients with a left ventricular ejection fraction between 30% and 35% benefit from a primary prevention implantable cardioverter defibrillator?
Int J Cardiol. 2014 Mar 1;172(1):253-4. doi: 10.1016/j.ijcard.2013.12.278..
Keywords: Comparative Effectiveness, Outcomes, Medical Devices, Heart Disease and Health, Chronic Conditions