National Healthcare Quality and Disparities Report
Latest available findings on quality of and access to health care
Data
- Data Infographics
- Data Visualizations
- Data Tools
- Data Innovations
- All-Payer Claims Database
- Healthcare Cost and Utilization Project (HCUP)
- Medical Expenditure Panel Survey (MEPS)
- AHRQ Quality Indicator Tools for Data Analytics
- State Snapshots
- United States Health Information Knowledgebase (USHIK)
- Data Sources Available from AHRQ
Search All Research Studies
Topics
- Cardiovascular Conditions (1)
- Healthcare Delivery (1)
- Heart Disease and Health (1)
- Intensive Care Unit (ICU) (1)
- Labor and Delivery (1)
- Medication (1)
- Neonatal Intensive Care Unit (NICU) (1)
- (-) Newborns/Infants (3)
- Nursing (1)
- Patient Safety (1)
- Practice Patterns (1)
- Quality Improvement (2)
- Quality Indicators (QIs) (1)
- (-) Quality of Care (3)
- Registries (1)
- Workflow (1)
AHRQ Research Studies
Sign up: AHRQ Research Studies Email updates
Research Studies is a compilation of published research articles funded by AHRQ or authored by AHRQ researchers.
Results
1 to 3 of 3 Research Studies DisplayedLake ET, Staiger DO, Cramer E
Association of patient acuity and missed nursing care in U.S. neonatal intensive care units.
The health outcomes of infants in neonatal intensive care units (NICUs) may be jeopardized when required nursing care is missed. The authors conducted a correlational study of using 2016 NICU registered nurse survey responses from the National Database of Nursing Quality Indicators. They found that 36% of nurses missed one or more care activities on their past shift. The most common activities missed involved patient comfort and counseling and parent education. They recommended that nurses' assignments account for patient acuity. NICU nurse staffing and work environments warrant attention to reduce missed care and promote optimal infant and family outcomes.
AHRQ-funded; HS024918.
Citation: Lake ET, Staiger DO, Cramer E .
Association of patient acuity and missed nursing care in U.S. neonatal intensive care units.
Med Care Res Rev 2020 Oct;77(5):451-60. doi: 10.1177/1077558718806743..
Keywords: Newborns/Infants, Neonatal Intensive Care Unit (NICU), Intensive Care Unit (ICU), Nursing, Quality Indicators (QIs), Quality of Care
Hansen JE, Brown DW, Hanke SP
Angiotensin-converting enzyme inhibitor prescription for patients with single ventricle physiology enrolled in the NPC-QIC registry.
This study examined trends in the routine use of angiotension-converting enzyme inhibitors (ACEI) during palliation of hypoplastic left heart syndrome, which is considered controversial. The authors used patients enrolled in the National Pediatric Cardiology Quality Improvement Collaborative (NPC-QIC) registry from 2008 to 2016 who had been prescribed ACEI between stage 1 palliation (stage I Norwood procedure) discharge and stage 2 palliation (stage II superior cavopulmonary anastomosis procedure) admission. ACEI prescriptions declined from 45% in the pre-2010 period to 36.8% from 2011 to 2016. No difference was found in interstage mortality, change in atrioventricular valve regurgitation, or change in ventricular dysfunction between groups. Atrioventricular septal defect, and preoperative mechanical ventilation were associated with increased ACEI prescription.
AHRQ-funded; HS021114.
Citation: Hansen JE, Brown DW, Hanke SP .
Angiotensin-converting enzyme inhibitor prescription for patients with single ventricle physiology enrolled in the NPC-QIC registry.
J Am Heart Assoc 2020 May 18;9(10):e014823. doi: 10.1161/jaha.119.014823..
Keywords: Newborns/Infants, Medication, Heart Disease and Health, Cardiovascular Conditions, Practice Patterns, Registries, Quality Improvement, Quality of Care
Herrick HM, Lorch S, Hsu JY
Impact of flow disruptions in the delivery room.
The goal of this study was to identify the impact of flow disruptions during neonatal resuscitation and to determine their association with key process and outcome measures. Delivery-room resuscitations of neonates less 32 weeks gestational age were video recorded for observation. Results showed that flow disruptions occurred frequently during neonatal resuscitation and recommendations included measuring flow disruptions as a feasible method to assess the impact of human factors in the delivery room and to identify modifiable factors and practices to improve patient care.
AHRQ-funded; HS023538; HS026491; HS026625; HS023806.
Citation: Herrick HM, Lorch S, Hsu JY .
Impact of flow disruptions in the delivery room.
Resuscitation 2020 May;150:29-35. doi: 10.1016/j.resuscitation.2020.02.037.
.
.
Keywords: Workflow, Labor and Delivery, Newborns/Infants, Patient Safety, Healthcare Delivery, Quality Improvement, Quality of Care